ionization chamber

https://doi.org/10.1351/goldbook.I03190
A @[email protected] which employs an electric field for the @[email protected] at the electrodes of charges associated with the @[email protected] produced in the sensitive volume by @[email protected], without charge multiplication. The solid @[email protected] (2Π, 4π ) subtended when using the detector, is sometimes specified.
Source:
PAC, 1982, 54, 1533. (Glossary of terms used in nuclear analytical chemistry (Provisional)) on page 1545 [Terms] [Paper]